Giant HVAC

Air Conditioning System Tune-Up Special

18 Point Cooling System Check Up Includes:

  1. Thermostat – Check temperature display accuracy and tighten lose wires that can cause short cycling.
  2. System Performance / Split Temp – Measure temperature differential across evaporator coil.  Split should be 18-20°.
  3. Air Filter – Clean or replace air filter, and inspect air return for air restrictions. (New filter will incur an additional charge)
  4. Air Ducts – Check for air leaks. A cool attic during warm months is typically a sign of duct leakage.
  5. Electrical Box – Tighten connections and check for metal fatigue and electrical overheating (bluish-green discoloration).
  6. Condensate Drain – Check drain for debris blockage and look for key signs of drain overflow (rust or stains).
  7. Air Distribution – Check airflow and inspect areas where homeowners are experiencing a lack of comfort.
  8. Plenum – Check the duct transitions for leakage caused by system vibration or poor installation materials.
  9. Evaporator Coil – Check for bacteria build-up, formicary corrosion, galvanic corrosion, and leaking refrigerant oil.  Dirty coils reduce efficiency and decrease air quality.
  10. Run Capacitors – Test all capacitors for proper microfarad “µf” capacity (max permitted ± 10%) and inspect for signs of leakage or bulging.
  11. Refrigerant – Confirm and record refrigerant pressures if system fails system performance testing or any of the visual coil inspections. Add up to 1lb of R-410a refrigerant if necessary.
  12. Condenser Coil – Examine coil for straightness and cleanliness, and leaking refrigerant oil.  Take and evaluate outside split temp.
  13. Compressor – Test amp draw and compare it to max on data plate.  Tighten loose wires at contactor.
  14. Safety Controls – Check all panel switches and pressure controls to make sure they are functioning properly.
  15. Condenser Motor – Check the amp draw and compare it to the max rating.   Check bearings and lubricate motor as necessary.
  16. Blower Motor – Same check as condenser motor along with blower wheel inspection and bacteria build-up.
  17. Insulation – Confirm all internal unit insulation is secure.  Check suction line insulation.
  18. Contactor – Look for worn or pitted points and check for discoloration or severely burnt wires.

Our Promise

100% Satisfaction Guarantee. If you are not completely satisfied with our repair or service, we will promptly address your needs or refund your service call fee.

Refer Your Buddy Program

Get 10% off for you and your friends with a referral!

Schedule Service

Call (773) 539-9629 to schedule a no obligations appointment.

Specials

10% OFF for Veterans*
10% OFF for Seniors*

*Must be mentioned at time of appointment

Financing Available

First 6 months same as cash